Faulty Fire Alarms
Are you frustrated that your fire alarm keeps going off, or that all the lights on the panel are flashing? You are not alone.
Faulty Fire Alarms
We frequently receive enquiries about faulty alarms. First and foremost, the initial step in resolving the issue is to understand why your fire alarm is malfunctioning. In this article, we’ll help you identify potential problems and guide you toward a solution.
Fire Alarm Testing Regulations
In the United Kingdom, fire alarm regulations (BS 5839-1) outline how often these systems should be tested. Failing to follow these regulations could result in fines, liability for any related issues, or even the voiding of your insurance. Therefore, as a business owner, it’s crucial to ensure compliance.
To meet these regulations, your fire alarm must be serviced every six months. Once the service is completed, you should receive a certification confirming that your system is in order, along with a report showing any areas for improvement. Moreover, regular weekly testing should be conducted by a designated person, and the results should be logged (download a free logbook at the bottom of the article). This log not only helps identify faults in the system early on and track any trends. Consequently, addressing these issues promptly ensures that your fire alarm remains in optimal working order which in turn reduces ongoing maintenance costs.
What is Covered in a Fire Alarm Service
A fire alarm system includes several components, and the specific tests required depend on your setup. For consistency, perform a weekly test on the same day and time. If any abnormalities are noticed, such as inaudible sounds, record them immediately. Furthermore, the test should last between 5 and 60 seconds to ensure that personnel recognise it as a test.
Key areas to check include:
- System Control Panel – Check for errors and confirm that everything is functioning correctly.
- Call Points – Ensure the call points work properly and are undamaged. Additionally, If you have multiple call points, rotate them during weekly tests to ensure each one can trigger the alarm and create awareness for evacuation.
- Alarm Sounder – Confirm that the alarm sounds when activated. By conducting regular testing at the same time each week helps employees identify any issues with the alarm’s audibility.
- Voice Alarms – Test voice alarms weekly. Make sure they sound correct and log any issues.
- Circuits – Inspect circuits and wires for damage, which could potentially be caused by rodents, water ingress, or old cabling.
- Batteries – Verify that all batteries are operating at peak performance.
- Detectors – Test all detectors to ensure they function correctly.

Who to Call for a Faulty Fire Alarm
When your fire alarm malfunctions, contact your fire protection company immediately if you have a service contract with them. If you don’t, reach out to a reputable fire protection company like Rhino Fire Control Ltd. Always choose a BAFE-approved company to ensure that your system is professionally repaired and certified. After addressing the issue, make sure to record the faulty alarm and the resolution in your fire logbook. This documentation helps demonstrate your business’s compliance with safety regulations.
The Bleeping Alarm…
If your fire alarm starts beeping, have your company’s designated person report the fault immediately. The contractor will then diagnose the problem and fix any issues with the faulty fire alarm.
If the noise isn’t coming from the fire alarm, it could be the smoke detector. Although smoke detectors don’t make noise themselves, a fault will trigger a warning on the main control panel, often starting with a beep or buzz.
False alarms can also occur due to the smoke detector’s position or environmental factors like steam, dust, or other particles in the air. In these cases, switching to a different type of detector might be more effective. Our expert team can guide you through this process and recommend the best fire detectors for your business.

Seeing Red…
If you notice your smoke detector’s red LED activated, this would show the fire alarm has been activated or the detector is faulty. A BAFE engineer should inspect the alarm to ensure compliance, and record this in your fire logbook to maintain your adherence to BS 5839-1 standards. Keeping everything recorded and traceable is essential for regulatory compliance.
Sometimes, fire alarms can activate for no apparent reason. If this is happening, don’t hesitate to contact us. We offer a 24/7 emergency callout line to contract customers because staying compliant and safe is crucial. If you are a Rhino Fire Control customer, our platinum policy provides peace of mind. Protecting your people, property, and profit is our priority. Our primary goal is fire prevention in the workplace because your business is our business.